“Oshino survived full hour. Logger stopped. Oshino lamp survived entire exposure.”

In an independent lab test, 5 samples of Oshino and GE 4626 were tested per MIL-DTL-6363H 3.6.5.3, MIL-STD-202 Method 214.  Test parameters:

• Vibration Level: D
• Vibration type:  Random(operational) Axes: Vertical
• Frequency: 50-2000 Hz
• Duration: 60 mins
• GRMS: 11.96

                        Oshino             GE
Sample 1         30                    9.37
Sample 2         60                    19
Sample 3         60                     3
Sample 4         60                     1
Sample 5         37                     18
Average Operating Time to Failure - Minutes

             Oshino: 49.4                GE: 10.07

Oshino 4626 Specifications 
Design Voltage [V]  28
Watts [W] 150
Filament CC-6
Base  CR-2
Lens Clear Fluted
MOL (mm) 70
Diameter (mm) 114
AIPBCP (cd) 25,000
Beam Spread (H x V) (deg) 40 x 9
Average Life Hours  300

 


Source: Intertek Report no. 101988034GRR-001, 13 March 2015.